This model represents a simplified residential dwelling for a family of 5 members, modeled as a single thermal zone, located in Brussels, Belgium. The building envelope model is based on the BESTEST case 900 test case. but it is scaled to an area that is four times larger. The rectangular floor plan is 12 m by 16 m. Internal walls are configured such that there are around 12 rooms in the building. The builiding further contains 24 m2 of windows on the south facade.

An air-to-water modulating heat pump of 15 kW nominal heating capacity extracts energy from the ambient air to heat up the floor heating emission system. A fan blows ambient air through the heat pump evaporator and circulation pump pumps water from the heat pump to the floorr when the heat pump is operating.

Click here to view detailed documentation.

Available Test Scenarios

Time Periods

peak_heat_day typical_heat_day

Electricity Prices

constant dynamic highly_dynamic

Dependencies

The Modelica model for this test case uses the Modelica Standard Library and the Modelica IDEAS Library.

The FMU for this test case is compiled by the open-source JModelica.org.